DETAIL KOLEKSI

Geologi dan analisis kestabilan lereng berdasarkan sifat fisik dan kuat geser tanah pada hilir bendungan Jatigede, Kecamatan Jatigede, Kabupaten Sumedang, Provinsi Jawa Barat

5.0


Oleh : Yorna Harysany

Info Katalog

Nomor Panggil : 898/TG/2018

Penerbit : FTKE - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2018

Pembimbing 1 : Hidartan

Pembimbing 2 : Harry Pramudito

Subyek : Slope stability;Engineering geology

Kata Kunci : Jatigede dam, soil physical properties, soil mechanical properties, slope, safety factor

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2018_TA_GL_07212220_Halaman-Judul.pdf 23
2. 2018_TA_GL_07212220_Bab-1.pdf 6
3. 2018_TA_GL_07212220_Bab-2.pdf
4. 2018_TA_GL_07212220_Bab-3.pdf
5. 2018_TA_GL_07212220_Bab-4.pdf
6. 2018_TA_GL_07212220_Bab-5.pdf
7. 2018_TA_GL_07212220_Daftar-Pustaka.pdf 3
8. 2018_TA_GL_07212220_Lampiran.pdf

G erakan tanah merupakan bencana yang membahayakan yang sering tejadi, longsorterjadi karena adanya pergerakan tanah yang memiliki lereng yang curam, lahanterbuka, tingkat kelembaban tinggi. Bentuk dan kemiringan lereng, kekuatan materialsangat berkaitan dengan kestabilan lereng. Daerah penelitian berada pada lapangan“Hilir Bendungan Jatigede”, yaitu secara administratif terletak pada KabupatenSumedang, Provinsi Jawa Barat. Dalam penelitian ini adalah untuk menentukankestabilan lereng. Oleh karena itu, mengetahui dan menyajikan data geologi dangeologi teknik, sifat fisik dan mekanika tanah, serta faktor keamanan lereng padadaerah penelitian sangat penting. Tahapan yang dilakukan adalah penyelidikanlapangan dan membuat peta geologi dengan geologi teknik, pengambilan sampelhandbor dan uji lapangan yang kemudian dilakukan uji laboratorium sifat fisik tanahuntuk mendapat nilai berat isi tanah, kadar air, batas cair, batas plastis, indeksplastisitas. Uji mekanika tanah dengan Uji Geser Langsung untuk mendapat nilaikohesi, sudut geser dalam; dan derajat tingkat pelapukan menurut International forRock Mechanic (ISRM), 1978. Dari hasil analisa sifat fisik tanah nilai berat isi tanahsebesar 2633.9 kN/m3-2735 kN/m3, kadar air sebesar 38%-56%, batas cair sebesar55%-78%, batas plastis 28%-44%, dengan indeks plastisitas sebesar 25%-32%.Analisa kuat geser tanah dengan nilai kohesi sebesar 40 kPa-156 kPa dan sudut geserdalam sebesar 30.5°-55.4°. Kestabilan lereng pada daerah penelitian terbagi menjaditiga, yaitu kelas stabil dengan nilai FK= 1.277–2.400, kelas kritis dengan nilai FK=1.091 dan kelas labil dengan nilai FK= 0.379. Maka lokasi tersebut di zonasikansetelah diketahui nilai faktor keamanan

L and movement is a catastrophic disaster that often occur, landslide occurs due toland movement on a steep, arid and humid slope. Shape, degree of slope and rockforming materials is critically related to the slope stability. Area of interest is locatedin “Downstream Jatigede Dam”, whilst administratively is located in SumedangDistrict, West Java Province. The goal of this research is to determine the slopestability. Hence, to figure out with present the geological or geotechnical data,physical properties and mechanics of the soil, as well as the safety factor on theslope of the area of interest. The stages that were done in the research are;investigation and production of geological and geotechnical maps, picking of handboresamples and series of field testing that were later tested again in lab conditionsto find the value of soil mass, water content, liquid limit, plastic limit and plasticityindex. Soil mechanical testing, as well as direct shear test, to find the cohesion valueand internal friction angle; and the degree of weather in accordance to Internationalfor Rock Mechanic (ISRM), 1978. The outcomes of the soil physical propertiesanalysis are; soil mass is 2633.9 kN/m3-2735 kN/m3, water content is 28% - 56%,liquid limit is 55% - 78%, plastic limit is 28% - 44%, plasticity indeks is 25% - 32%.Soil direct shear analysis with cohesion value is 40 kPa – 156 kPa and internalsliding angle is 30.5°-55.4°. Slope stability in the area of interest is categorized into3 zones; Stable zone with safety factor is 1.277 – 2.400, critical zona with a safetyfactor is 1.091 and unstable zone with a safety factor is 0.379. So the location hasbeen zonated since the safety factor was known.

Bagaimana Anda menilai Koleksi ini ?