Analisa tegangan pipa pada outlet heat exchanger menuju inlet gas scrubber menggunakan software caesar II


Oleh : Arief Nur Hidayat

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2017

Pembimbing 1 : Jamal M. Affif

Subyek : Gas pipelines;Mechanical engineering

Kata Kunci : pipe stress analysis, piping system, process piping, caesar II

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2017_TA_STM_061001500501_Halaman-Judul.pdf
2. 2017_TA_STM_061001500501_Lembar-Pengesahan.pdf
3. 2017_TA_STM_061001500501_Bab-1_Pendahuluan.pdf 3
4. 2017_TA_STM_061001500501_Bab-2_Tinjauan-Pustaka.pdf
5. 2017_TA_STM_061001500501_Bab-3_-Metodologi-Penelitian.pdf
6. 2017_TA_STM_061001500501_Bab-4_Analisis-dan-Pembahasan.pdf
7. 2017_TA_STM_061001500501_Bab-5_Kesimpulan.pdf
8. 2017_TA_STM_061001500501_Daftar-Pustaka.pdf 1
9. 2017_TA_STM_061001500501_Lampiran.pdf

S istem pemipaan pada CNG (Compressed Natural Gas) plant adalah suatu hal yang sangat penting, karena fungsi dari pemipaan ini adalah mengalirkan fluidagas yang akan digunakan sebagai bahan bakar PLTMG (Pembangkit ListrikTenaga Mesin Gas). Sehingga harus dilakukan analisa tegangan agar tidak terjadikegagalan pada sistem pemipaan tersebut. Analisa tegangan pada pipa tersebutmeliputi simulasi yang terjadi akibat adanya beban dari temperatur (thermal load),tekanan (pressure load), tipe pipe support, dan jarak antar pipe support.Metodologi penelitian ini meliputi studi literatur, pengumpulan data, inputparameter dan pemodelan emnggunakan software Caesar II, analisa tegangan padapipa, verifikasi hasil, simulasi dan menganalisa hasil simulasi. Mengacu pada datadesain dari P & ID (Piping and Instrument Diagram) dengan tekanan dalam desain300 psi, temperatur desain 180◦F untuk diameter pipa 8 inch sebagai jalur utamasesuai dengan hasil perhitungan didapat ketebalan 0,322 inch ≈ 8,18 mm (Sch 40).Diameter pipa 2 Inch sebagai konek instrumentasi, hasil perhitungan didapat 0,153inch ≈ 3,91 m (Sch 40). Diameter pipa 0,75 inch sebagai saluran Drain dan Venthasil perhitungan didapat 0,153 inch ≈ 8,18 mm (Sch 80). Jalur pipa dinyatakanaman karena karena tegangan yang terjadi yaitu sebesar 13632,8 psi < daritegangan ijinnya yaitu 20000 psi.

T he piping system of CNG (Compressed Natural Gas) plant is a veryimportant thing, because the function of this piping is to pass gas fluid to be usedas fuel of PLTMG (Pembangkit Listrik Tenaga Mesin Gas). So it must be donestress analysis in order to avoid failure in the piping system. The stress analysis ofthe pipe includes simulations that result from loads of temperature (thermal load),pressure load (pressure load), pipe support type, and distance between pipesupport.This research methodology covers literature study, data collection,parameter input and modeling using Caesar II software, pipeline stress analysis,verification of results, simulation and analysis of simulation results.Referring to the design data of P & ID (Piping and Instrument Diagram) withdesign pressure 300 psi and design temperature 180 ◦F for 8 inch pipe diameter asmain line according to calculation result obtained thickness 0,322 inch ≈ 8,18 mm(Sch 40). Diameter of 2 Inch pipe as instrumentation connection, the calculationresults obtained 0.153 inch ≈ 3.91 m (Sch 40). Diameter of 0.75 inch pipe as drainand vent line, calculation obtained 0.153 inch ≈ 8.18 mm (Sch 80). The piping issafe because actual stress 13632.8 psi