DETAIL KOLEKSI

Simulasi karakteristik termodinamika refrigerasi adsorpsi karbon aktif-ammonia


Oleh : Prayudi

Info Katalog

Subyek : Thermodynamic;Energy conservation

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2010

Pembimbing 1 : Bambang Teguh Prasetyo

Kata Kunci : adsorption refrigeration, activated carbon-ammonia, thermal conductivity, generator temperature, COP

Status Posting : Published

Status : Tidak Lengkap


File Repositori
No. Nama File Hal. Link
1. 2010_TS_MTM_161061005_Halaman-Judul.pdf 9
2. 2010_TS_MTM_161061005_Lembar-Pengesahan.pdf 3
3. 2010_TS_MTM_161061005_Bab-1_Pendahuluan.pdf
4. 2010_TS_MTM_161061005_Bab-2_Tinjauan-Pustaka.pdf
5. 2010_TS_MTM_161061005_Bab-3_Metodologi-Penelitian.pdf
6. 2010_TS_MTM_161061005_Bab-4_Analisis-dan-Pembahasan.pdf
7. 2010_TS_MTM_161061005_Bab-5_Kesimpulan-dan-Saran.pdf
8. 2010_TS_MTM_161061005_Daftar-Pustaka.pdf 3
9. 2010_TS_MTM_161061005_Lampiran.pdf

K Konservasi energi merupakan solusi alternatif untuk mengurangi penggunaan energi fosil. Salah satu upaya adalah pengembangan sistem refrigerasi adsorpsi dengan panas buang sebagai sumber energi Tujuan dari penelitian ini adalah melakukan simulasi numerik karakteristik termodinamika sistem refrigerasi adsorpsi. Metode penelitian diawali dengan menetapkan kondisi proses untuk menentukan kapasitas pendinginan, dilanjutkan dengan mendesain generator adsorber. Dari data proses dan geometri generator, disusun model matematika untuk menentukan distribusi temperatur di dalam generator dan konsentrasi ammonia. Dari hasil simulasi tersebut di atas dapat dibuat simulasi COP. Pasangan adsorbat-adsorben yang dipilih adalah karbon aktif -ammonia. Simulasi dilakukan pada kondisi temperatur evaporasi 7°C, temperatur kondensasi 48°C, dan temperatur awal desorpsi 32°C. Generator - adsorber didesain berbentuk lempeng empat persegi panjang, dan sumber panas dialirkan dan dua nisi. Proses perpindahan panas diasumsikan satu dimensi dan tidal( ada produksi panas. Kapasitas adsorpsi dihitung dengan menggunakan model Dibinin Astakhov. Temperatur fluida pemanas divariasikan dari 80°C, 90°C, 100°C, 110°C, 120°C, sedangkan konduktivitas termal karbon aktif divariasikan dari 0,3 Wim.K, 0,5 W/m.K, 0,7 W/m.K. Hasil simulasi numerik menunjukkan bahwa, jika temperatur generator naik, waktu siklusnya bprtambat, jika konduktivitas termal karbon aktif meningkat, maka waktu siklusnya berkuiapg. Jika temperatur generator-adsorber meningkat maka COP menurun(dan jika kondUktivitas termal karbon aktif naik, maka COP meningkat. Setiap 1 kg/ammo-ilia menghasilkan efek refrigerasi 0,627 kW. Efek refrigerasi maksimumiterj pada ter eratur ge erator adsorber 90°C, dan rata-rata COP adalah 0,6117.

E Energy conservation is an alternative solution to reduce the use of fossil energy. One of the efforts is the development of an adsorption refrigeration system with exhaust heat as an energy source. The purpose of this research is to perform a numerical simulation of the thermodynamic characteristics of the adsorption refrigeration system. The research method begins with determining the process conditions to determine the cooling capacity, followed by designing an adsorber generator. From the process data and generator geometry, a mathematical model was developed to determine the temperature distribution in the generator and the ammonia concentration. From the simulation results above, a COP simulation can be made. The selected adsorbate-adsorbent pair is activated carbon -ammonia. Simulations were carried out at an evaporation temperature of 7°C, a condensation temperature of 48°C, and an initial desorption temperature of 32°C. The generator - the adsorber is designed in the form of a rectangular plate, and the heat source is supplied and has two nozzles. The heat transfer process is assumed to be one-dimensional and non-heat production. The adsorption capacity is calculated using the Dibinin Astakhov model. The temperature of the heating fluid is varied from 80°C, 90°C, 100°C, 110°C, 120°C, while the thermal conductivity activated carbon was varied from 0.3 Wim.K, 0.5 W/mK, 0.7 W/mK. The numerical simulation results show that, if the generator temperature increases, the cycle time decreases, if the thermal conductivity of activated carbon increases, the cycle time increases. . If the generator-adsorber temperature increases, the COP decreases (and if the thermal conductivity of activated carbon increases, then the COP increases. Every 1 kg/ammo-ilia produces a refrigeration effect of 0.627 kW. The maximum refrigeration effect at the adjustable generator adsorber is 90°C, and the average COP is 0.6117.

Bagaimana Anda menilai Koleksi ini ?