DETAIL KOLEKSI

Studi banding SNI 1726:2021 dengan SNI 1726:2019 pada desain ketahanan gempa struktur bangunan apartemen di Tangerang

4.5


Oleh : Ristanti Prita Puspita

Info Katalog

Subyek : Buildings - Earthquake effects;Apartment houses

Penerbit : FTSP - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2021

Pembimbing 1 : Agus Hadi Santosa Wargadipura

Kata Kunci : earthquake resistant, planning regulations, values of basic, SNI

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2021_TS_MTS_151011710023_Halaman-Judul.pdf
2. 2021_TS_MTS_151011710023_Lembar-Pengesahan.pdf 3
3. 2021_TS_MTS_151011710023_Bab-1_Pendahuluan.pdf
4. 2021_TS_MTS_151011710023_Bab-2_Tinjauan-Pustaka.pdf
5. 2021_TS_MTS_151011710023_Bab-3_Metodologi-Penelitian.pdf
6. 2021_TS_MTS_151011710023_Bab-4_Analisis-dan-Pembahasan.pdf
7. 2021_TS_MTS_151011710023_Bab-5_Kesimpulan.pdf
8. 2021_TS_MTS_151011710023_Daftar-Pustaka.pdf
9. 2021_TS_MTS_151011710023_Lampiran.pdf

P Peraturan perencanaan bangunan tahan gempa mengalami perubahan mengikuti perkembangan keilmuan dan kondisi alam yang berubah. SNI 1726:2019 yang disahkan pada tanggal 19 Desember 2019 merupakan peraturan terbaru untuk perencanaan bangunan tahan gempa menggantikan SNI 1726:2012. Pada penulisan tesis ini akan dilakukan studi banding pada bangunan apartemen di Tangerang dengan perhitungan menggunakan kedua SNI tersebut. Studi ini bertujuan untuk mendapatkan besarnya perbandingan nilai-nilai gaya geser dasar (base shear), distribusi gaya gempa (story shear), simpangan antar lantai (story drift) menggunakan analisa statik dan dinamik serta untuk mengetahui perbandingan presentase rasio perbandingan penggunaan penulangan kolom dan balok pada bangunan apartemen yang ditinjau menggunakan kedua SNI tersebut. Metodologi yang digunakan yaitu menggunakan studi literatur khususnya SNI 1726:2012, SNI 1726:2019, SNI 1727:2013, SNI 2847:2019 dan SNI 2052:2017. Studi literatur juga dilakukan menggunakan jurnal-jurnal yang relavan terhadap studi banding ini. Pengumpulan data berupa gambar kerja (shop drawing) untuk bangunan tipikal yang kemudian dimodelkan menggunakan ETABS 18. Pembebanan dilakukan sesuai dengan SNI 1727:2013, kemudian dianalisis menggunakan perangkat lunak ETABS 18 untuk mendapatkan nilai base shear, story displacement dan gaya-gaya dalam. Perhitungan penulangan dilakukan menggunakan perangkat lunak CSI Detail 18. Nilai base shear yang didapatkan akan digunakan untuk melakukan perhitungan story shear, nilai story displacement digunakan untuk perhitungan story drift dan gaya-gaya dalam yang didapatkan pada ETABS 18 akan digunakan untuk perhitungan penulangan pada CSI Detail 18. Hasil dari studi banding tersebut adalah semua perhitungan menggunakan SNI 1726:2019 menghasilkan nilai yang lebih besar daripada perhitungan menggunakan SNI 1726:2012 baik dengan analisa statik maupun dinamik. Perbandingan nilai base shear analisa statik arah x dan y sebesar 8,52% (selisih 1.442,44 kN), base shear analisa dinamik arah x sebesar 27,67% (selisih 3.996,50 kN) dan arah y sebesar 27,67% (selisih 3.996,49 kN). Perbandingan nilai story shear dan story drift disajikan dalam tabel dan grafik. Pebedaan rasio penulangan kolom dan balok masing-masing sebesar 13,77% dan 9,90%.

E Earthquake-resistant building planning regulations have changed following scientific developments and changing natural conditions. SNI 1726: 2019 which was ratified on December 19, 2019 is the latest regulation for earthquake resistant building planning replacing SNI 1726: 2012. In this final project a comparative study will be conducted on apartment buildings in Tangerang with calculations using the two SNIs. This study aims to compare the values of basic shear (basic shear), earthquake force distribution (story shear), deviation between floors (story shifts) using static and dynamic analysis and to see the ratio of the ratio of column and beam usage in apartment buildings. who use both SNIs. The methodology used is to use literature studies, especially SNI 1726: 2012, SNI 1726: 2019, SNI 1727: 2013, SNI 2847: 2019 and SNI 2052: 2017. Literature studies are also carried out using journals relevant to this comparative study. Collecting data in the form of shop drawings for typical buildings which are then modeled using ETABS 18. Loading is carried out in accordance with SNI 1727: 2013, then analyzed using the ETABS 18 software to obtain the value of base shear, floor displacement and internal forces. The reinforcement calculation is done using CSI Detail 18 software.The base shear value obtained will be used to calculate the story shear, the story displacement value is used to calculate story drift and the internal forces obtained in ETABS 18 will be used for the calculation of reinforcement in CSI Detail 18. The result of the comparative study is that all calculations using SNI 1726: 2019 produce a value that is greater than the calculation using SNI 1726: 2012 both with static and dynamic analysis. Comparison of the basic shear analysis value of the x and y direction static analysis of 8.52% (difference of 1,442.44 kN), the basic shear analysis of the x direction of dynamic analysis of 27.67% (the difference of 3,996.50 kN) and the y direction of 27.67 % (difference of 3,996.49 kN). Comparison of story and story slide values is presented in tables and graphs. The difference in the ratio of column and beam reinforcement was 13.77% and 9.90%, respectively.

Bagaimana Anda menilai Koleksi ini ?