DETAIL KOLEKSI

Evaluasi permasalahan buckling dan thermal elongation pada liner di lapangan panas bumi O sumur GEB-10


Oleh : Muhammad Luthfi Afdhitama Fawwaz

Info Katalog

Nomor Panggil : 1210/TP/2019

Penerbit : FTKE - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2019

Pembimbing 1 : Sugiatmo Kasmungin

Pembimbing 2 : Widia Yanti

Subyek : Geothermal structure;Petroleum engineering

Kata Kunci : buckling, compressive load, drilling technology, geothermal, thermal elongation

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2019_TA_TM_071001400114_Halaman-Judul.pdf 17
2. 2019_TA_TM_071001400114_BAB-1.pdf 2
3. 2019_TA_TM_071001400114_BAB-2.pdf
4. 2019_TA_TM_071001400114_BAB-3.pdf 4
5. 2019_TA_TM_071001400114_BAB-4.pdf 11
6. 2019_TA_TM_071001400114_BAB-5.pdf 2
7. 2019_TA_TM_071001400114_DAFTAR-PUSTAKA.pdf 2
8. 2019_TA_TM_071001400114_LAMPIRAN.pdf

T Teknologi pemboran sumur panas bumi banyak mengadopsi teknologi pemboran sumur-sumur minyak dan gas. Sumur-sumur panas bumi biasanya dibor dengan diameter lebih besar, lebih dalam, dan ditujukan untuk waktu produksi lebih panjang daripada sumur minyak dan gas. Perencanaan yang baik merupakan kunci keberhasilan dalam operasi pemasangan casing dan liner. Pada pengeboran panas bumi salah satu masalah yang dihadapi adalah liner yang digunakan tidak bisa menahan beban rangkaian yang telah diprogram untuk proses produksi, serta tingginya suhu pada formasi. Lapangan O sumur GEB-10 merupakan lapangan panas bumi, maka diperlukan pemilihan grade (material) casing yang tepat untuk dapat menahan suhu formasi. Perhitungan yang digunakan untuk menentukan jenis grade casing adalah dengan melakukan perhitungan beban Compressive, batas buckling dan Thermal Elongation. Pada perhitungan liner 10 3/4” dengan panjang trayek 917 m didapatkan hasil beban compressive sebesar 125994,37 lbs dan batas bucklingnya 71402,48 lbs dan thermal elongation sebesar 2,27 m, sedangkan pada liner 8 5/8” dengan panjang trayek 1195 m didapatkan hasil beban compressive sebesar 97298,45 lbs dan batas bucklingnya 38515,1 lbs dan thermal elongation sebesar 2,96 m. Dari perhitungan pada liner 10 3/4” dan 8 5/8” tersebut mengalami indikasi helical buckling sehingga harus diantisipasi dengan cara pengurangan panjang liner menjadi 537 m untuk liner 10 3/4 dan 444 m untuk liner 8 5/8”.

G Geothermal well drilling technology adopts many oil and gas well drilling technologies. Geothermal wells are usually drilled with a larger diameter, deeper, and intended for a longer production time than oil and gas wells. Good planning is the key to success in casing and liner installation operations. In geothermal drilling, one of the problems faced is that the liner used cannot withstand the load of the programmed circuit for the production process, and the high temperature of the formation. Field O GEB-10 well is a geothermal field, so the selection of appropriate grade (material) casing is needed to be able to withstand formation temperatures. Evaluation of the installation of the liner to determine whether the liner has buckling or not, and know the steps to prevent buckling. The calculation used to determine the type of casing grade is by calculating the Compressive load, buckling limit and Thermal Elongation. In the calculation of the liner 10 3/4 "with a length of 917 m, the compressive load results are 125994.37 lbs and the buckling limit is 71402.48 lbs and thermal elongation is 2.27 m, while on the liner 8 5/8" the length of the route is 1195 m obtained the results of a compressive load of 97298.45 lbs and the buckling limit of 38515.1 lbs and thermal elongation of 2.96 m. From the calculations on the 10 3/4 "and 8 5/8" liners, there is an indication of helical buckling so it must be anticipated by reducing the length of the liner to 537 m for the 10 3/4 and 444 m for the 8 5/8 liner, or by replacing higher grade liner.

Bagaimana Anda menilai Koleksi ini ?