Studi penyetelan relai diferensial pada transformator PT Chevron Pacific Indonesia
Penerbit : FTI - Usakti
Kota Terbit : Jakarta
Tahun Terbit : 2008
Pembimbing 1 : Pribadi Kadarisman
Subyek : Differrential equations
Kata Kunci : transformer, electrical energy, relay, system, substation
Status Posting : Published
Status : Tidak Lengkap
No. | Nama File | Hal. | Link |
---|---|---|---|
1. | 2008_TA_STE_06204073_Halaman-Judul.pdf | ||
2. | 2008_TA_STE_06204073_Lembar-Pengesahan.pdf | ||
3. | 2008_TA_STE_06204073_Bab-1_Pendahuluan.pdf | ||
4. | 2008_TA_STE_06204073_Bab-2_Tinjauan-Pustaka.pdf |
|
|
5. | 2008_TA_STE_06204073_Bab-3_Metodologi-Penelitian.pdf |
|
|
6. | 2008_TA_STE_06204073_Bab-4_Analisis-Haisl-dan-Pembahasan.pdf |
|
|
7. | 2008_TA_STE_06204073_Bab-5_Kesimpulan-dan-Saran.pdf | ||
8. | 2008_TA_STE_06204073_Daftar-Pustaka.pdf | ||
9. | 2008_TA_STE_06204073_Lampiran.pdf |
|
M Mutu dari suatu sistem tenaga listrik di ukur dari segi kontinuitas pelayanan, pengendalian dan perawatan yang baik. Kontinuitas pelayanan yang baik dapat diperoleh bila semua komponen sistem tenaga dapat bekerja dengan baik pada semua kondisi, baik pada kondisi normal maupun abnormal. Pada kondisi abnormal sistem proteksi berperan penting dalam mendeteksi setiap gangguan yang terjadi dan melepaskan bagian-bagian yang terganggu tersebut dari sistem. Transformator tenaga merupakan salah satu komponen utama pada gardu induk. Gangguan pada transformator tenaga harus dapat diamankan agar tidak mengganggu sistem kelistrikan dalam menyalurkan energi listrik ke beban yang lain. Relai diferensial pada transformator tenaga merupakan relai pengaman untuk mendeteksi gangguan internal sehingga relai diferensial digolongkan sebagai proteksi utama pada transformator . Dalam tugas akhir ini dibahas mengenai setelan dan error mismatch relai diferensial pada Gardu Induk Central Duri di switchgear #3 di PT Chevron Pacific Indonesia (PT CPI).
T The quality of electric power systems is measured from the angle of continuity of service, good control and maintenance. The good continuity of service can be obtained if all the components of power systems can operate well in every situation and condition, either in normal or in abnormal condition. In abnormal condition, the protection system has an important role in detecting every disturbances and release parts which is disturbanced from the system. The power transformer is the main component in substation. The disturbances in transformer should have been saved to not disturb the system when distribution the electric energy to others load. The differential Relay on the power transformer is a protection relay to detect internal disturbance which can be group in the major of transformer protection. This final assignment study about the setting and mismatch error of differential Relay in substation of Central Duri at switchgear #3 at PT Chevron Pacific Indonesia (PT CPI).