DETAIL KOLEKSI

Pemantauan dan pengendalian inkubator bayi prematur berbasis aplikasi android


Oleh : R. Liguta Frans.M

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2021

Pembimbing 1 : Shinta dewi J

Subyek : Arduino (Programmable controller) - Designs and plans

Kata Kunci : arduino mega, nodemcu, premature baby, fuzzy, incubator, blynk

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2021_TA_STE_062001904030_Halaman-Judul.pdf
2. 2021_TA_STE_062001904030_Lembar-Pengesahan.pdf
3. 2021_TA_STE_062001904030_Bab-1_Pendahuluan.pdf -1
4. 2021_TA_STE_062001904030_Bab-2_Tinjauan-Pustaka.pdf
5. 2021_TA_STE_062001904030_Bab-3_Metodologi-Penelitian.pdf
6. 2021_TA_STE_062001904030_Bab-4_Analisa-dan-Pembahasan.pdf
7. 2021_TA_STE_062001904030_Bab-5_Kesimpulan-dan-Saran.pdf
8. 2021_TA_STE_062001904030_Daftar-Pustaka.pdf
9. 2021_TA_STE_062001904030_Lampiran.pdf

B Bayi prematur adalah bayi yang lahir lebih awal dari waktu yangseharusnya, yaitu 9,25 bulan atau 37 minggu. Dunia luar yang memiliki suhu danlingkungan yang jauh berbeda dari saat di dalam rahim ibu menyebabkan bayiyang lahir prematur lebih mudah mengalami penurunan suhu karena tubuhnyayang belum bisa beradaptasi. Sistem ini dibuat agar bayi yang lahir secaraprematur dapat merasakan suhu seperti halnya berada saat di dalam kandungan(32-35 ºC), sistem ini dirancang dengan menggunakan sistem fuzzy dalammengontrol suhu ruang inkubator. Arduino Mega bertanggung jawab mengaturkeluaran dimmer lampu berdasarkan pembacaan sensor load cell dan sensor suhuDS18B20 serta mengukur pembacaan suhu tubuh menggunakan sensorMLX90614, NodeMCU untuk mengukur pembacaan detak jantung bayimenggunakan modul sensor MAX30100 dan NodeMCU sebagai penerima hasildari data yang dikirim oleh Arduino Mega. Selanjutnya proses pengiriman dataakan menggunakan NodeMCU yang dapat terhubung dengan jaringan internet dandata pembacaan yang diterima akan dikirim ke platform Blynk dan diaksesmelalui smartphone. NodeMCU mampu memberikan notifikasi yang berupa popup dan juga suara yang aktif secara bersamaan, jika nilai pengukuran dari sensorload cell, suhu inkubator, detak jantung dan suhu tubuh berada di luar rangenormal. Berdasarkan hasil pengujian sensor yang telah dilakukan, diperolehnilai..error rata–rata dari pembacaan sensor suhu tubuh (MLX 90614) sebesar0,24 % , error rata–rata pembacaan sensor detak jantung (MAX 3100) sebesar1,97% , nilai..error rata–rata dari pembacaan sensor berat sebesar 0,119 % , errorrata–rata pembacaan sensor suhu ruang sebesar 0,174 %. Pada pengendalian suhuinkubator berdasarkan pengujian yang dilakukan lama waktu dari suhu 29 oCdengan beban 1000 gr menuju 35 oC berkisar 1 menit 45 detik sedangkan denganbeban 2500 gr menuju 32 oC berkisar 1 menit 5 detik.

P Premature babies are babies born earlier than the expected time, which is 9.25months or 37 weeks. The outside world, which has a temperature and environmentthat is much different from when it was in the mother's womb, causes babies bornprematurely to experience a decrease in temperature because their bodies havenot been able to adapt. This system is designed so that babies born prematurelycan feel the temperature as if they were in the womb (32-35 ºC), this system isdesigned using a fuzzy system to control the temperature of the incubator room.Arduino Mega is responsible for regulating the output of the light dimmer basedon the load cell sensor readings and the DS18B20 temperature sensor andmeasuring body temperature readings using the MLX90614 sensor, NodeMCU tomeasure the baby's heart rate readings using the MAX30100 sensor module andNodeMCU as the recipient of the results of the data sent by Arduino Mega.Furthermore, the data transmission process will use a NodeMCU which can beconnected to the internet network and the received reading data will be sent to theBlynk platform and accessed via a smartphone. NodeMCU is able to providenotifications in the form of pop ups as well as sound that is active simultaneously,if the measurement values from the load cell sensor, incubator temperature, heartrate and body temperature are outside the normal range. Based on the results ofsensor testing that has been carried out, the average error value of the bodytemperature sensor reading (MLX 90614) is 0.24%, the average error of the heartrate sensor reading (MAX 3100) is 1.97%, the average error of the weight sensorreading is 0.119%, the average error of the room temperature sensor reading is0.174 %. In controlling the incubator temperature, based on tests carried out, thelength of time from a temperature of 29 ºC with a load of 1000 gr to 35 oC rangesfrom 1 minute 45 seconds while with a load of 2500 gr to 32 ºC it ranges from 1minute 5 seconds.

Bagaimana Anda menilai Koleksi ini ?