Perancangan sistem instalasi listrik pada sistemtier 4 dengan auto bus transfer pada panel low voltage distribution panel proyek new data center bca


Oleh : Erwin Irwandi

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2023

Pembimbing 1 : Chairul Gagarin Irianto

Pembimbing 2 : Ishak Kasim

Subyek : Fault tolerance (Engineering);Electricity - Installation

Kata Kunci : Data center, tier 4, LVDP, designing

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2023_TA_STE_062002104016_Halaman-Judul.pdf 11
2. 2023_TA_STE_062002104016_Lembar-Pengesahan.pdf 1
3. 2023_TA_STE_062002104016_Bab-1_Pendahuluan.pdf
4. 2023_TA_STE_062002104016_Bab-2_Tinjauan-Pustaka.pdf
5. 2023_TA_STE_062002104016_Bab-3_Metodologi-Penelitian.pdf
6. 2023_TA_STE_062002104016_Bab-4_Analisis-dan-Pembahasan.pdf
7. 2023_TA_STE_062002104016_Bab-5_Kesimpulan.pdf 1
8. 2023_TA_STE_062002104016_Daftar-Pustaka.pdf 1
9. 2023_TA_STE_062002104016_Lampiran.pdf

T TIER.panel- Low Voltage Distribution Panel (LVDP) (PDU-IT) untukbagaimana merancang dan cara melakukan pengujian system control Automatic Transfer Switch (ATS) dan bus transfer secara manual maupun automatis pada panel LVDP-A1-1. Tier 4 (Fault Tolerant Site Infrastructure),(UPS)tidak. Low Voltage Distribution Panel (LVDP)sub-(SDP). merancang sistem data center diperlukannya menentukan komponen proteksi dan speksifikasi komponen, Setelah komponen telah dipilih maka langkah berikutnya adalah memulai desain sistem dari segi bentuk panel sampai dengan logic sistem.

P PT Bank BCA Tbk has prepared a data center that refers to the standards andcertifications set by the Uptime Institute, there are four criteria that we know,namely the term TIER.To supporting the needs of the data center, electrical panelsare needed which include Low Voltage Distribution Panel (LVDP) to the PanelDistribution Unit Server (PDU-IT) Panel to supply the server needs in the datacenter. Therefore it is important to know how to design and how to test theAutomatic Transfer Switch (ATS) control system and bus transfer manually orautomatically on the LVDP-A1-1 panel. Tier 4 (Fault Tolerant Site Infrastructure),which only has a downtime tolerance of 30 minutes a year, with an uptime rate of99.995%. It has a raised floor, UPS and backup generator and has a path system forhot and cold air exhaust. The security level is high because it has a 24-hour securitysystem, and is not vulnerable to planned or unplanned disturbances. Low VoltageDistribution Panel (LVDP) is a panel that receives electrical power fromtransformers and diesel generators and then divides the electrical power to sub-subpanels Sub Distribution Panel (SDP). Before designing a data center system, it isnecessary to determine the protection components and component specifications,after the components have been selected, the next step is to start the system designin terms of panel shape to system logic.

Bagaimana Anda menilai Koleksi ini ?