DETAIL KOLEKSI

Evaluasi casing design pada sumur NOK lapangan NNF


Oleh : Adi Satrio Iman Yogatama

Info Katalog

Nomor Panggil : 1312/TP/2020

Penerbit : FTKE - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2020

Pembimbing 1 : Ir. Abdul Hamid, M.T

Pembimbing 2 : Ir. Pauhesti Rusdi, M.T.

Subyek : Oil well casing;Oil wells - Testing

Kata Kunci : casing, collapse, burst, tension, optimalisasi

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2020_TA_STP_071001600003_Halaman-Judul.pdf
2. 2020_TA_STP_071001600003_Lembar-Pengesahan.pdf
3. 2020_TA_STP_071001600003_BAB-1_Pendahuluan.pdf
4. 2020_TA_STP_071001600003_BAB-2_Tinjauan-Umum.pdf
5. 2020_TA_STP_071001600003_BAB-3_Kerangka-Konsep.pdf
6. 2020_TA_STP_071001600003_BAB-4_Metode.pdf
7. 2020_TA_STP_071001600003_BAB-5_Kesimpulan.pdf
8. 2020_TA_STP_071001600003_Daftar-Pustaka.pdf
9. 2020_TA_STP_071001600003_Lampiran.pdf

S Sumur NOK merupakan sumur eksplorasi vertikal yang berada di lapanganNNF pada region Balikpapan. Dilakukannya pemboran sumur ini bertujuan untukmemproduksikan hidrokarbon minyak bumi pada lapisan zona antiklin Y. Dalampenelitian yang dilakukan oleh penulis, casing design adalah bahasan utama yangakan diteliti (dalam hal ini dievaluasi) dengan menghitung grade casing yangterpasang pada sumur kemudian memastikan apakah grade casing yang terpasangsudah layak digunakan. Pada sumur NOK ini menggunakan casing yang biasadigunakan dalam pemboran yaitu surface casing, intermediate casing, productioncasing. Parameter yang akan diperhitungkan adalah tekanan yang berasal dari luarcasing (collapse), tekanan yang berasal dari dalam casing (burst) dan tension.Metode yang digunakan untuk menghitung tekanan yang bekerja pada casingadalah maximum load. Hasil perhitungan optimasi pada casing ini berdasarkansafety factor dari perusahaan yang dimana harga dari safety factor burst sebesar 1,0,collapse 1,0 dan tension 1,3. Hasil dari optiomasi pada perhitungan casing didapathasil surface casing 13 3/8” H-40 48 ppf memiliki safety factor collapse sebesar2,3, burst sebesar 1,8, dan tension sebesar 5,4. Dapat disimpulkan bahwa pada padasurface casing 20” dapat menahan tekanan dari sumur. Pada intermediate casing 95/8” H-40 36 ppf hasil dari perhitungan casing memiliki safety factor collapsesebesar 1,4 , burst sebesar 1,3, dan tension sebesar 2,6. Dapat disimpulkan bahwapada intermediate casing 13 3/8 dapat menahan tekanan karena telah memenuhistandar safety factor pada perusahaan. Dan pada liner casing 7” K-55 26 ppf hasildari perhitungan casing memiliki safety factor collpase sebesar 1.7, burst sebesar1,2 dan tension 2,7. Pada casing liner 7” tidak dilakukan optimasi karena sudahmemenuhi standar safety factor pada perusahaan.

W Well NOK is a vertical exploration well which located on field NNF ofBalikpapan region, East Borneo. This well was drilled in order to producing thehydrocarbon of crude oil on the anticline layer “Y”. In this research whichconducted by writer, casing design is the main topic discussion inspected (in thiscase in form of evaluation) by calculating the installed casing grade in the well thenensure that the installed casing grade is proper to run. The NOK well uses a casingwhich is commonly used in drilling, namely surface casing, intermediate casing,production casing. The parameters that will be taken into account are the pressurethat comes from outside (collapse), the pressure that comes from inside the casing(burst) and tension. The method used to calculate the pressure acting on the casingis the maximum load. The calculation results on this casing are based on the safetyfactor of the company where the nominal of the safety factor burst is 1.0, collapse1.0 and tension 1.3. The results of optimization on the casing calculation obtainedthe results of surface casing of 13 3/8“ H-40 48 ppf having a safety factor collapseof 2.3, a burst of 1.8, and a tension of 5.4. It can be concluded that on the casingsurface 13 3/8“ is able to withstand the pressure of the well because it has meet thesafety factor standards in the company. At the intermediate casing 9 5/8“ H-40 36ppf the results of the casing calculation have a safety factor collapse of 1.4, a burstof 1.3, and a tension of 2.6. It can be concluded that at the intermediate casing 133/8 is able to withstand the pressure that can cause damage because it has met thesafety factor standard in the company. And on the casing liner 7 “K-55 26 ppf theresults of the casing calculation have a collapse safety factor of 1.7, a burst of 1.2and a tension of 2.7. In the 7 “liner case no optimization is done because it meetsthe safety factor standards in the company

Bagaimana Anda menilai Koleksi ini ?