DETAIL KOLEKSI

Pengaruh perbedaan perlakuan aplikasi bonding terhadap ketebalan bonding pada radiograf periapika (Laporan penelitian)

5.0


Oleh : Lyvia Juliana

Info Katalog

Nomor Panggil : 616.075 7 JUL p

Penerbit : FKG - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2014

Pembimbing 1 : drg. Rosalina T., M.Si, Ph.D

Pembimbing 2 : drg. Octarina, M.Si

Subyek : Radiology

Kata Kunci : Radiography, bonding agent, bonding thickness, secondary caries

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2014_TA_KG_04010125_Bab-5-Hasil-Penelitian.pdf
2. 2014_TA_KG_04010125_Bab-6-Pembahasan.pdf
3. 2014_TA_KG_04010125_Lampiran.pdf
4. 2014_TA_KG_04010125_Daftar-Pustaka.pdf
5. 2014_TA_KG_04010125_Bab-7-Kesimpulan-dan-Saran.pdf
6. 2014_TA_KG_04010125_Bab-4-Metode-Penelitian.pdf
7. 2014_TA_KG_04010125_Bab-3-Kerangka-Teori,-Konsep-dan-Hipotesis.pdf
8. 2014_TA_KG_04010125_Bab-2-Tinjauan-Pustaka.pdf
9. 2014_TA_KG_04010125_Bab-1-Pendahuluan.pdf
10. 2014_TA_KG_04010125_Halaman-Judul.pdf

I Interpretasi radiograf antara bonding yang yang terlalu tebal dengan tumpatan komposit seringkali keliru diartikan sebagai karies sekunder, sehingga akhirnya praktisi membongkar tambalan tersebut.Oleh sebab itu dilakukan penelitian mengenai efek perbedaan perlakuan dalam pengaplikasian bonding agar tercipta ketebalan yang baik dan tidak diduga sebagai karies sekunder secara radiografis. Penelitian eksperimental laboratorik menggunakan 12 gigi premolar utuh.Preparasi dilakukan dg membuat boks proksimal pada sisi mesial dan distal sehingga didapat 24 sampel. Jumlah tersebut dibagi jadi 4 kelompok dg perlakuan berbeda.

R Radiograph is used as a supporting equipment to strenghen diagnosis. Radiograph interpretation between bonding thieckness and composite filling often misunderstood as secondary caries, thereby dentist break down the restoration the objective of this research is to examine the diferrent effects of dental bonding agent application method taken with periapical radiography, thus creating a good thickness being mistaken as secondary caries. yhis laboratory research used 12 premolar teeth. Proximal box were made in mesial and distal siders of each tooth. the sample was devided into four groups with different treatment. such bonding that applied maxilimally withhout given any air flow (BAI). bonding that applied maximally with given an air flow (BA2), bonding that applied minimally without given any air flow (BB1), and bonding that applied minimally with given an air flow (BB2). Each sample were digitally exposed and there were statistically significant differences between bonding thickness with amount of bonding.

Bagaimana Anda menilai Koleksi ini ?