Subyek : Efficiency analysis - cooling tower;Heat exchanger

Kata Kunci : service air compressor,instrument air compressor, cooling tower

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2011_TA_MS_06106003_1_Halaman-Judul.pdf 7
2. 2011_TA_MS_06106003_2_Bab1.pdf 4
3. 2011_TA_MS_06106003_3_Bab2.pdf
4. 2011_TA_MS_06106003_4_Bab3.pdf
5. 2011_TA_MS_06106003_5_Bab4.pdf 1
6. 2011_TA_MS_06106003_6_Daftar-Pustaka.pdf 1
7. 2011_TA_MS_06106003_7_Lampiran.pdf

C Cooling tower merupakan suatu alat penukar kalor yang memiliki tingkat pendinginan cukup tinggi. Pada sistem PLTGU PT. Indonesia Power UBP Priok terdapat sistem SAC (Service Air Compressor) yang digunakan untuk backup Instrument Air Compressor (IAC) pada sistem ini memiliki cooling tower yang mendinginkan fluida kerja. Cooling tower tersebut perlu dikaji ulang akan kinerjanya. Salah satu kinerja cooling tower yang perlu dikaji adalah efisiensinya.Dalam menghitung efisiensi cooling tower terdapat beberapa parameter penting seperti suhu udara, suhu air, laju aliran air dan udara. Pengambilan data . parameter tersebut harus dilakukan dengan _benar dikarenakan data tersebut adalah inti dari perhitungan efisiensi cooling tower.Pengambilan data dilakukan sebanyak 7 kali dengan selang waktu 3 menit. Pada analisa ini nilai variasi laju alir air dan udara didapat berdasarkan simulasi dikarenakan kondisi dl lapangan yang tidak memungkinkan. Dan hasil analisa didapat nilai efisiensi cooling tower tersebut jauh di bawah standar efisiensi cooling tower pada umumnya.

C Cooling tower is a heat exchanger which has a fairly high level of cooling. On systems PLTGU PT. Indonesia Power UBP Priok are the SAC system (Service Air Compressor) which is used for backup Instrument Air Compressor (IAC) in this system has a cooling tower that cools the working fluid. Cooling tower should be reviewed will be its performance. One cooling tower performance that needs to be studied is efficiency.In calculating the efficiency of cooling tower there are some important parameters such as air temperature, water temperature, water flow rate and air. Data retrieval . these parameters should be done with _benar because such data is the core of the calculation of the efficiency of cooling tower.Data is collected as much as 7 times with an interval of 3 minutes. In this analysis, the value of the variation rate of water and air flow obtained by the simulation because the condition of the field dl that is not possible. And the results of analysis shows the efficiency of the cooling tower is far below the standard cooling tower efficiency in general.