Perancangan ulang surface condenser PLTU 200 mw


Oleh : Fiko Ogi Riando

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2011

Pembimbing 1 : Bambang Teguh Prasetyo

Subyek : Mechanical engineering

Kata Kunci : redesign, surface condenser, 200 MW coal-fired power plant

Status Posting : Published

Status : Tidak Lengkap


File Repositori
No. Nama File Hal. Link
1. 2011_TA_STE_06105038_Halaman-Judul.pdf
2. 2011_TA_STE_06105038_Lembar-Pengesahan.pdf 2
3. 2011_TA_STE_06105038_Bab-1_Pendahuluan.pdf 5
4. 2011_TA_STE_06105038_Bab-2_Landasan-teori.pdf
5. 2011_TA_STE_06105038_Bab-3_Perancangan-Panas-dan-Mekanikal.pdf
6. 2011_TA_STE_06105038_Bab-4_Hasil-Peritungan.pdf
7. 2011_TA_STE_06105038_Bab-5_Kesimpulan-dan-Saran.pdf
8. 2011_TA_STE_06105038_Daftar-Pustaka.pdf 2
9. 2011_TA_STE_06105038_Lampiran.pdf

P Perancangan ulang surface condenser PLTU (Pembangkit Listrik Tenaga Uap) 200MW telah dilakukan. Di dalam suatu instalasi pembangkit listrik tenaga uap diperlukan suatu komponen yang membuat operasi siklus lebih efisien. Salah satu komponen tersebut adalah surface condenser. Fungsi utama dari surface condenser pada suatu instalasi pembangkit adalah mengkondensasikan uap keluar dari turbin sehingga dapat menyelamatkan sejumlah besar air penambah dan menciptakan tekanan keluar turbin rendah sehingga efisiensi siklus power plant akan naik. Sampai saat ini, penguasaaan dibidang surface condenser masih dirasa kurang, maka dalam Tugas Akhir ini penulis mencoba merancang sebuah surface condenser dengan satu pass divided. Dengan metode perhitungan yang digunakan untuk merancang surface condenser single pass divided ini adalah metode LMTD. Metode LMTD adalah metode yang diterapkan pada segmen-segmen sepanjang surface condenser. Dengan demikian sifat yang perk diperhatikan adalah perbedaan temperatur rata-rata dari air pendingin. Besar kecilnya kesalahan perhitungan jumlah tube sangat bergantung pada beda suhu air pendinginan yang ditentukan. Hasil perhitungan kemudian dibandingkan dengan hasil data yang sudah ada. Dari basil perbandingan jumlah tube menunjukkan bahwa metode LMTD ini dapat digunakan untuk menghitung surface condenser karena persentase kesalahannya hanya 3,74 %.

T The redesign of the 200MW Steam Power Plant (PLTU) surface condenser has been carried out. In a steam power plant installation, a component is needed to make the cycle operation more efficient. One of these components is the surface condenser. The main function of the surface condenser in a power plant installation is to condense the steam exiting the turbine so that it can save a large amount of additional water and create a low turbine outlet pressure so that the efficiency of the power plant cycle will increase. Until now, mastery in the field of surface condensers is still considered lacking, so in this Final Project the author tries to design a surface condenser with a single pass divided. With the calculation method used to design this single pass divided surface condenser is the LMTD method. The LMTD method is a method applied to segments along the surface condenser. Thus, the property that needs to be considered is the average temperature difference of the cooling water. The size of the calculation error in the number of tubes is very dependent on the specified cooling water temperature difference. The calculation results are then compared with the results of existing data. The results of the comparison of the number of tubes show that the LMTD method can be used to calculate the surface condenser because the percentage error is only 3.74%.