DETAIL KOLEKSI

Analisis arc flash 6.3 kv PT Holcim Indonesia TBK. Bogor, Jawa Barat


Oleh : Juliansyah Kennedy Sugiharto

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2018

Pembimbing 1 : Syamsir Abduh

Subyek : Electric engineering;Electric power distribution

Kata Kunci : arc flash, hubung singkat, gangguan, ppe analisis

Status Posting : Published

Status : Tidak Lengkap


File Repositori
No. Nama File Hal. Link
1. 2018_TA_STE_062001400045_Halaman-Judul.pdf
2. 2018_TA_STE_062001400045_Lembar-Pengesahan.pdf
3. 2018_TA_STE_062001400045_Bab-1_Pendahuluan.pdf
4. 2018_TA_STE_062001400045_Bab-2_Tinjauan-Pustaka.pdf
5. 2018_TA_STE_062001400045_Bab-3_Metodologi-Penelitian.pdf
6. 2018_TA_STE_062001400045_Bab-4_Analisis-Hasil-dan-Pembahasan.pdf
7. 2018_TA_STE_062001400045_Bab-5_Kesimpulan-dan-Saran.pdf 2
8. 2018_TA_STE_062001400045_Daftar-Pustaka.pdf

S Sistem proteksi merupakan suatu sistem pengaman terhadap peralatan listrik jika terjadi gangguan. Salah satu bahaya listrik adalah arc flash. Menurut IEEE 1584-2002 Arc flash merupakan ledakan panas, gas panas, dan logam cair yang diakibatkan oleh gangguan hubung singkat (short circuit) pada peralatan. Terdapat 3 kasus arc flash yang terjadi di PT Holcim Indonesia Tbk. Bogor, Jawa Barat. Penilitian ini bertujuan untuk mengetahui besar energi arc flash yang dibutuhkan sesuai dengan standar IEEE 1584-2002 untuk mengetahui besar energi serta mengklasifikasi kategori Personal Protective Equipment (PPE) bagi pekerja sesuai dengan standar NFPA 70E-2009. Studi ini akan coba diterapkan pada area finish mill 5 pada PT Holcim Indonesia Tbk. Bogor, Jawa Barat. Hasil penelitian menunjukkan pada area finish mill 5 nilai insiden energinya yaitu 16.92 cal/ pada BUS MD-1, 1.39 cal/ pada BUS RM-1 , 1.35 cal/ pada BUS FN-2, 2.17 cal/ pada BUS TR-71, 1.41 cal/ pada BUS TR-72, 1.34 cal/ pada BUS TR-73.

P Protection system is a safety system against electrical equipment in case of interference. One of the electrical hazards is the flash arc. According to IEEE 1584-2002 Arc flash is a blast of heat, hot gas, and liquid metal caused by short circuit interference (short circuit) on the equipment. There are 3 cases of arc flash that occurred in PT Holcim Indonesia Tbk. Bogor, West Java. This research is aimed to find out the amount of arc flash energy needed in accordance with IEEE 1584-2002 standard to know the energy and also classify Personal Protective Equipment (PPE) category for the workers according to NFPA 70E-2009 standard. This study will try to be applied to the 5th mill finishing area at PT Holcim Indonesia Tbk. Bogor, West Java. The results showed on the area of the finish mill 5 the value of the energy incident is 16.92 cal/ on BUS MD-1 , 1.39 cal/ on BUS RM-1 , 1.35 cal/ on BUS FN-2, 2.17 cal/ on BUS TR-71, 1.41 cal/ on BUS TR-72, 1.34 cal/ on BUS TR-73.

Bagaimana Anda menilai Koleksi ini ?