Pengaruh debit aliran air dari thermal storage terhadap pengkondisian udara pada ac mini chiller


Oleh : Brodjo Koeswardianto

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2016

Pembimbing 1 : Senoadi

Subyek : Refrigeration and refrigerating machinery

Kata Kunci : water flow, thermal storage, air conditioning

Status Posting : Published

Status : Tidak Lengkap


File Repositori
No. Nama File Hal. Link
1. 2016_TA_STM_06109051_Halaman-Judul.pdf 16
2. 2016_TA_STM_06109051_Lembar-Pengesahan.pdf
3. 2016_TA_STM_06109051_Bab-1_Pendahuluan.pdf 4
4. 2016_TA_STM_06109051_Bab-2_Tinjauan-Pustaka.pdf
5. 2016_TA_STM_06109051_Bab-3_Metodologi-Penelitian.pdf
6. 2016_TA_STM_06109051_Bab-4_Analisa-dan-Perhitungan.pdf
7. 2016_TA_STM_06109051_Bab-5_Kesimpulan.pdf
8. 2016_TA_STM_06109051_Daftar-Pustaka.pdf
9. 2016_TA_STM_06109051_Lampiran.pdf

T Tugas akhir ini membahas analisa dan penelitian tentang pengaruh debit aliran air dari Thermal Storage pada pengkondisian udara AC Mini Chiller. Tujuan dari penelitian ini untuk mengetahui penyerapan maksimum yang terjadi oleh air ketika Mini Chiller dalam keadaan kompresor tidak dihidupkan (discharge) serta lama waktu udara dingin yang dihasilkan setelah air didinginkan. Penelitian ini dilakukan dengan menganalisis Perpindahan panas dan Number of Transfer Unit dari sistem Mini Chiller pada saat kondisi kompresor tidak dihidupkan. Percobaan yang akan dilakukan dengan memvariasikan laju aliran volume air yang keluar dari 1,6 ltr/mnt sampai 2,2 Itr/mnt dengan selisih 0,2 ltr/mnt dengan cara mengatur putaran kran pada selang sampai didapatkan volume air yg didapatkan. Dari percobaan yang telah dilakukan, didapatkan data dan analisa grafik serta diperoleh Perpindahan panas tertinggi yaitu sebesar 1847,125 dan Number of Transfer Unit sebesar 1,901 pada laju aliran volume tertinggi yaitu 2,2 liter / menit. Jadi laju aliran volume chiller water berpengaruh terhadap Perpindahan panas (Qmax) dan Number of Transfer Unit NTU pada sisi FCU dari sistem thermal storage water chiller

T This thesis explores the analysis and research on the effect of flow rates Thermal Storage on Mini Chiller air conditioning . The purpose of this thesis was determine the maximum absorbtion occurs by water when Mini Chiller doing discharge as well as the length of time the cold air that is expelled after the water was cooled by the compressor. This research was conducted by analyzing Qmax and Number Of Transfer Units of Mini Chiller system conditions at the time when the compressor is turn off (discharge). The experiments will be carried out by varying the volume flow rate of water from 1.6 liters per minute to 2.2 liters per minute with a difference of 0.2 liters per minute with set the tap water from hose. From the experiments have been performed, the data and analysis chard obtained has earned the highest maximum of heat exchanger at 1847.125 and Number of Transfer Unit amounted to 1.901 on the highest volume flow rate 2.2 liters per minute.So The volume flow rate of water chiller effect on Qmax and Number Transfer Unit in FCU of Thermal Storage water chiller system.