DETAIL KOLEKSI

Analisis dan evaluasi sistem proteksi petir pada Gedung Wisma Maktour, Jakarta Timur


Oleh : Junar Ramadhan Raib

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2022

Pembimbing 1 : Maula Sukmawidjaja

Subyek : Lightning rods;Lightning rods

Kata Kunci : lightning protection system, electrostatic, grounding, SNI 2004

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2022_TA_STE_062001600038_Halaman-Judul.pdf 12
2. 2022_TA_STE_062001600038_Lembar-Pengesahan.pdf 3
3. 2022_TA_STE_062001600038_Bab-1_Pendahuluan.pdf 5
4. 2022_TA_STE_062001600038_Bab-2_Tinjauan-Pustaka.pdf 66
5. 2022_TA_STE_062001600038_Bab-3_Metodologi-Penelitian.pdf 50
6. 2022_TA_STE_062001600038_Bab-4_Analisis-dan-Pembahasan.pdf 48
7. 2022_TA_STE_062001600038_Bab-5_Kesimpulan.pdf 4
8. 2022_TA_STE_062001600038_Daftar-Pustaka.pdf 2
9. 2022_TA_STE_062001600038_Lampiran.pdf 14

P Petir merupakan peristiwa alam yang tidak dapat dihindari, sehingga dapatmenyebabkan kerusakan pada bangunan atau area yang terkena sambaran petirlangsung dan tidak langsung. Akibat dari sambaran petir, maka pentingnya suatusistem proteksi terhadap bahaya sambaran petir dengan menggunakan suatu alatyaitu sistem penangkal petir. Jenis-jenis proteksi petir ada berbagai macam,diantaranya jenis konvensional dan jenis elektrostatis, keduanya berfungsimengamankan gedung dari sambaran petir. Dalam penelitian ini berlokasi diGedung Wisma Maktour Jakarta Timur bertujuan untuk mengetahui tingkatkebutuhuhan proteksi petir dan keamanan seluruh bagian sistem proteksi petirpada Gedung Wisma Maktour kemudian dilakukan analisis dan evaluasi padasistem proteksi petir bangunanberdasarkan standar PUIPP 1983, SNI 03-7015-2004, dan Peraturan Menteri Tenaga Kerja No : PER 02/MEN/1989 agar dapatdilakukan rekomendasi perbaikan yang sesuai standar keselamatan dan keamanan.Berdasarkan hasil penelitian, radius proteksi penangkal petir elektrostatis padaGedung Wisma Maktour sudah dapat melindungi bangunan secara keseluruhan,namun berdasarkan metode bola bergulir terdapat sisi bangunan yang tidakterproteksi secara keseluruhan. Kondisi efek korosi pada down conductortergolong baik, namun pada pemasangan yang tertimbun konstruksi bangunanmenyebabkan tidak dapat dilakukan pengujian fisik secara berkala dan jaminankeamanan. Pada grounding memiliki nilai tahanan sebesar 0.96 𝛺 sehinggasudah sesuai pada aturan dan standar yang digunakan, tetapi perlunya dilakukanpenyempurnaan fisik agar terhindar dari efek korosi. Dari kerusakan yang dimilikisebaiknya pihak pengelola gedung segera melakukan perbaikan sesuai standardan keamanan mengingat Gedung Wisma Maktour memiliki R=15 menyebabkansangat wajibnya akan proteksi petir.

L Lightning is an unavoidable natural event, so it can cause damage tobuildings or areas affected by direct and indirect lightning strikes. As a result oflightning strikes, it is important to have a protection system against the dangers oflightning strikes by using a tool, namely a lightning rod system. There are varioustypes of lightning rods, including conventional and electrostatic types of lightningrods, both of which function to protect buildings from lightning strikes. In thisstudy, located in the Wisma Maktour Building, East Jakarta, the aim was todetermine the level of lightning protection and security for all parts of thelightning protection system at the Wisma Maktour Building. Then an analysis andevaluation was carried out on the lightning protection system of the Wismabuilding based on the 1983 PUIPP standard, SNI 03-7015-2004. , and Regulationof the Minister of Manpower No: PER 02/MEN/1989 so that recommendations forimprovements can be made in accordance with safety and security standards.Based on the results of the study, the radius of protection of the electrostaticlightning rod at the Wisma Maktour Building was able to protect the building as awhole, but based on the rolling ball method there were sides of the building thatwere not fully protected. The condition of the corrosion effect on the downconductor is quite good, however, in the installation that is buried under buildingconstruction, it is impossible to carry out regular physical tests and guaranteesafety. The grounding has a resistance value of 0.96 so that it is in accordancewith the rules and standards used, but it is necessary to make physicalimprovements to avoid the effects of corrosion. From the damage that is owned,the building manager should immediately make repairs according to standardsand security considering that the Wisma Maktour Building has an R = 15, whichmakes lightning protection very mandatory.

Bagaimana Anda menilai Koleksi ini ?