DETAIL KOLEKSI

Perancangan, pembuatan, dan pengujian inkubator bayi dengan menggunakan sumber daya listrik konvensional

0.0


Oleh : Christon E. H. Manurung

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2020

Pembimbing 1 : Chalilullah Rangkuti

Pembimbing 2 : Rosyida Permatasari

Subyek : Electric lines;Energy resources

Kata Kunci : design, baby’s incubator, incandescent lamp, microcontroller.

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2020_TA_STM_061001500026_Halaman-Judul.pdf
2. 2020_TA_STM_061001500026_Lembar-Pengesahan.pdf
3. 2020_TA_STM_061001500026_Bab-1_Pendahuluan.pdf 3
4. 2020_TA_STM_061001500026_Bab-2_Tinjauan-Pustaka.pdf
5. 2020_TA_STM_061001500026_Bab-3_Metodologi-Penelitian.pdf
6. 2020_TA_STM_061001500026_Bab-4_Analisis-dan-Pembahasan.pdf
7. 2020_TA_STM_061001500026_Bab-5_Kesimpulan.pdf
8. 2020_TA_STM_061001500026_Daftar-Pustaka.pdf
9. 2020_TA_STM_061001500026_Lampiran.pdf

B Bayi yang lahir sebelum usia kehamilan standar disebut bayi prematur. Bayiyang lahir prematur membutuhkan perawatan intensif karena belum dapat menjagasuhu tubuhnya sendiri yang berakibat sangat rentan terhadap penyakit . Dikarenakankemampuan tubuh bayi dalam menjaga keseimbangan antara produksi panas dankehilangan panas untuk mempertahankan suhu tubuh pada batas normal(termoregulasi) belum begitu baik, maka dibutuhkan inkubator untuk mambantumenjaga suhu disekitar bayi tetap terjaga. Suhu didalam ruang inkubator harusdisesuaikan dengan kebutuhan dengan kebutuhan bayi yaitu antara 32°C - 37°C.Inkubator bayi dibuat menggunakan bahan acrylic dengan ketebalan 3 mm. Untukmemanaskan udara didalam inkubator digunakan dua buah lampu pijar. Agartemperatur udara didalam inkubator dapat diketahui dan diatur, digunakan alatmikrokontroler BR6 dan termokopel sebagai sensor suhu. Pada penelitian inidigunakan lampu pijar dengan tiga daya yaitu 40 Watt, 60 Watt, dan 75 Watt.Pengambilan data dilakukan sebanyak tiga kali pada setiap kombinasi lampu pijar.Penelitian dilakukan dengan cara pengamatan dan analisa data suhu didalam inkubatoryang dapat dicapai pada waktu yang ditentukan. Didapatkan hasil suhu didalam ruanginkubator sebesar 31.9°C dalam waktu 15 menit dengan menggunakan dua buah lampupijar 40 Watt.

B Babies born before standard gestational age are called premature babies.Premature babies need intensive care because they have not been able to maintain theirown body temperature which is very vulnerable to disease. The premature babiescouldn’t maintain the balance between heat production and heat loss in their bodies atnormal limit. Therefore, the incubator is needed to maintain the temperature around thebabies. The temperature in the incubator room must be adjusted to the baby's needs,which is between 32°C - 37°C. Baby incubators are made from acrylic material with athickness of 3 mm. To heat the air in an incubator, two incandescent lamps are used.Therefore, the air temperature inside the incubator can be known and adjusted by usinga BR6 microcontroller and thermocouple as a temperature sensor. In this study,incandescent lamps with three power are used 40 Watt, 60 Watt, and 75 Watt. Datawere collected three times for each combination of incandescent lamps. The study wasconducted by observing and analyzing the temperature data in the incubator which canbe achieved at the specified time. The results obtained in the incubator temperature of31.9°C within 15 minutes using two 40 Watt incandescent lamps.

Bagaimana Anda menilai Koleksi ini ?