DETAIL KOLEKSI

Uji performa pipa tanam penukar kalor sistem siklus terbuka menggunakan metoda cfd


Oleh : Nor Fajri

Info Katalog

Subyek : Pipe;Aerodynamics

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2023

Pembimbing 1 : Rosyida Permatasari

Kata Kunci : new and renewable energy, heat transfer, buried air-soil heat exchanger pipe, coefficient of perform

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2023_TS_MTM_161011810001_Halaman-Judul.pdf
2. 2023_TS_MTM_161011810001_Lembar-Pengesahan.pdf
3. 2023_TS_MTM_161011810001_Bab-1_Pendahuluan.pdf
4. 2023_TS_MTM_161011810001_Bab-2_Tinjauan-Pustaka.pdf
5. 2023_TS_MTM_161011810001_Bab-3_Metodologi-Penelitian.pdf
6. 2023_TS_MTM_161011810001_Bab-4_Analisis-Hasil-dan-Pembahasan.pdf
7. 2023_TS_MTM_161011810001_Bab-5_Kesimpulan-dan-Saran.pdf
8. 2023_TS_MTM_161011810001_Daftar-Pustaka.pdf
9. 2023_TS_MTM_161011810001_Lampiran.pdf

S Sumber daya energi global konvensional menipis dengan cepat, selain adanya kerugian tambahan dari volatilitas harga. Permintaan yang tinggi dan cadangan yang terbatas akan menyebabkan menipisnya sumber daya energi, sehingga sangat diharapkan untuk meminimalkan penggunaan konsumsi energi bermutu tinggi. Penggunaan energi baru dan terbarukan merupakan salah satu cara untuk menyelamatkan bumi dari efek berbahaya akibat pemanasan global dan penipisan lapisan ozon. Penelitian ini bertujuan untuk menguji performa pipa tanam penukar kalor sistem siklus terbuka menggunakan metoda CFD. Metoda yang akan digunakan adalah metoda CFD (EAHE) yakni suatu metode perpindahan panas dari lapisan tanah. Pipa Steel dan PVC akan ditanam di dalam tanah, kemudian udara dialirkan melalui pipa menggunakan blower menggunakan 4 variasi kecepatan udara yaitu 1 m/s Re 9355,43 , 2 m/s Re 18710,87, 3 m/s Re 28066,30 dan 5 m/s Re 46777,16. dan dihasilkan COP maksimal material steel sebesar 0,948 dan minimal 0,934, sedangkan pada material PVC sebesar maksimal 0,978 dan minimal 0,924

C Conventional global energy resources are depleting rapidly, coupled with additional challenges posed by price volatility. High demand and limited reserves will lead to the exhaustion of energy resources, making it essential to minimize the use of high-quality energy consumption. The utilization of new and renewable energy is one approach to saving the planet from the harmful effects of global warming and ozone layer depletion. This study aims to evaluate the performance of buried heat exchanger pipes in an open-cycle system using the CFD method. The method employed is CFD (EAHE), a heat transfer technique involving soil layers. Steel and PVC pipes will be buried in the ground, with air passed through the pipes using a blower at four different airspeed variations: 1 m/s (Re 9355.43), 2 m/s (Re 18710.87), 3 m/s (Re 28066.30), and 5 m/s (Re 46777.16). The results showed a maximum COP of 0.948 and a minimum of 0.934 for steel pipes, whereas PVC pipes exhibited a maximum COP of 0.978 and a minimum of 0.924.

Bagaimana Anda menilai Koleksi ini ?