DETAIL KOLEKSI

Analisis kestabilan lereng dua dimensi dengan metode elemen hingga PIT 3 Timur Banko Barat di PT Bukit Asam Tbk.


Oleh : Herlina Putri Pratiwi

Info Katalog

Nomor Panggil : 660/TT/2019

Penerbit : FTKE - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2019

Pembimbing 1 : Masagus Ahmad Azizi

Pembimbing 2 : Bani Nugroho

Subyek : Slope - Stability analysis

Kata Kunci : 2D slope stability analysis, finite element method, strength reduction factor, 3 nodes triangles, 6

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2019_TA_TB_073001300048_Halaman-Judul.pdf
2. 2019_TA_TB_073001300048_bab-1.pdf
3. 2019_TA_TB_073001300048_bab-2.pdf 20
4. 2019_TA_TB_073001300048_bab-3.pdf 9
5. 2019_TA_TB_073001300048_bab-4.pdf
6. 2019_TA_TB_073001300048_bab-5.pdf
7. 2019_TA_TB_073001300048_Daftar-Pustaka.pdf
8. 2019_TA_TB_073001300048_lampiran.pdf

A Analisa kestabilan lereng di Pit 3 Timur Banko barat bertujuan untuk menghitung kestabilan lereng tersebut untuk mendesain ulang agar tidak terjadilongsor. Penelitian ini menggunakan metode elemen hingga dalam bentuk duadimensi, tipe element 3 Nodes dan 6 Nodes untuk pengolahan data yaitu kohesi,sudut gesek dalam, young’s modulus, poisson ratio yang diperoleh dari hasil logborgeoteknik.Pada analisis lereng keseluruhan dilakukan pada 6 penampang yangberpusat pada bagian utara Pit.Selisih hasil tipe 3 Nodes dan 6 Nodes adalah 0.14.Analisis elemen hingga menyatakan bahwa daerah highwall pada Pit 3 TimurBanko Barat dalam keadaan tidak stabil karna SRF < 1 dan PK > 66.8. Dariperbandingan analisis tipe elemen, didapatkan bahwa tipe 6 Nodes Triangles lebihcocok digunakan pada analisis kestabilan lereng dengan FEM dibandingkan dengan3 Nodes Triangles

S Slope stability analysis in Pit 3 East Banko west aims to calculate thestability of the slope to redesign so that there is no landslide. This study uses finiteelement methods in two dimensions, type 3 Nodes and 6 Nodes for dataprocessing namely cohesion, internal friction angle, young's modulus, poissonratio obtained from the results of a geotechnical logbor.The overall slope analysis was carried out in 6 cross sections centered onthe northern part of the pit. 3Nodes type results and 6 Nodes were 0.14. Finiteelement analysis states that the highwall area at Pit 3 East Banko Barat isunstable due to SRF <1 and PK> 66.8. From the comparison of element typeanalysis, it was found that type 6 Triangles Nodes were more suitable for analysisof slope stability with FEM compared to 3 Nodes Triangles

Bagaimana Anda menilai Koleksi ini ?