DETAIL KOLEKSI

Analisis distorsi gelombang harmonik tegangan pada penggunaan motor dc dalam proses rolling mills di PT X


Oleh : Rizdam Firly Muzakki

Info Katalog

Subyek : Machinery industry;Electrical engineering

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2022

Pembimbing 1 : Chairul G Irianto

Kata Kunci : dc motor, rolling mills, total harmonic distortion (thd)

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2022_TS_MTE_162012000001_Halaman-Judul.pdf 8
2. 2022_TS_MTE_162012000001_Lembar-Pengesahan.pdf 9
3. 2022_TS_MTE_162012000001_Bab-1_Pendahuluan.pdf 4
4. 2022_TS_MTE_162012000001_Bab-2_Tinjauan-Pustaka.pdf 9
5. 2022_TS_MTE_162012000001_Bab-3_Metodologi-Penelitian.pdf 9
6. 2022_TS_MTE_162012000001_Bab-4_Analisis-dan-Pembahasan.pdf 15
7. 2022_TS_MTE_162012000001_Bab-5_Kesimpulan-dan-Saran.pdf 2
8. 2022_TS_MTE_162012000001_Daftar-Pustaka.pdf 3
9. 2022_TS_MTE_162012000001_Lampiran.pdf 34

P PT X merupakan salah satu pabrik yang bergerak dalam bidang industri manufaktur baja. Pada salah satu tahapan produksinya, terdapat proses penggilingan atau rolling mills, dimana motor DC digunakan sebagai penggerak utamanya. Sebuah rangkaian penyearah diperlukan untuk menyuplai tegangan motor DC, sedangkan penggunaan komponen semikonduktor pada rangkaian penyearah berisiko menimbulkan distorsi harmonik, yang berdampak buruk pada peralatan elektronik seperti PLC, UPS, dan sebagainya. Pengamatan awal dilakukan untuk mengetahui nilai Total Harmonic Distortion (THD) pada panel incoming 6KV yang menyuplai daya ke motor DC. Dari hasil pengamatan diketahui nilai THD tegangan belum memenuhi standar yang ditetapkan dalam IEEE 519-2014. Penelitian ini bertujuan unutk menganalisis THD tegangan yang dihasilkan dari penggunaan rangkaian penyearah terkendali dan motor DC sebagai beban yang paling dominan, serta merancang desain filter untuk memitigasinya. Software MATLAB akan digunakan untuk mensimulasikan rangkaian dan menganalisis nilai THD tegangan yang dihasilkan. Dari hasil simulasi diketahui rangkaian motor DC 400KW, 450KW, dan 600KW menghasilkan nilai THD tegangan sebesar 9,35%, 14,23%, dan 12,28%. Adapun standar yang ditetapkan adalah sebesar 8% untuk kategori tegangan dibawah 1kV. Filter pasif single-tuned dirancang untuk rangkaian tersebut untuk menurunkan nilai THD tegangan pada masing-masing motor. Pemasangan filter efektif menurunkan nilai THD tegangan pada rangkaian motor DC 400KW, 450KW, dan 600KW menjadi sebesar 4,34%, 5,38%, dan 6,35%.

P PT X is one of the factories engaged in the steel manufacturing industry. At one of its production's stage, there is a steel milling process, where a DC motor is used as the main driver. A rectifier circuit is needed to supply DC voltage to motor, while the use of semiconductor components in the rectifier circuit has the risk of causing harmonic distortion, which has a negative impact on electronic equipment such as PLC, UPS, and so on. Preliminary observations were made to determine the value of Total Harmonic Distortion (THD) on the incoming 6KV panel that supplies power to the DC motor. From the observations it is known that the voltage THD value does not meet the standards set in IEEE 519-2014. This study aims to analyze the THD of the voltage resulting from the use of a controlled rectifier circuit and a DC motor as the most dominant load, and to design a filter design to mitigate it. MATLAB software will be used to simulate the circuit and analyze the resulting voltage THD value. From the simulation results, it is known that the 400KW, 450KW, and 600KW DC motor circuits produce voltage THD values of 9.35%, 14.23%, and 12.28% respectively. The standard set is 8% for the voltage category below 1kV. A single-tuned passive filter is designed for the circuit to lower the THD value of the voltage on each motor. The installation of the filter effectively reduces the THD voltage value of 400KW, 450KW, and 600KW DC motor circuits to 4.34%, 5.38%, and 6.35% respectively.