DETAIL KOLEKSI

Analisis eksperimental karakteristik termodinamika refrigerasi adsorpsi dengan menggunakan karbon aktif-ammonia

4.0


Oleh : Suhengki

Info Katalog

Subyek : Thermodynamics;Refrigeration and refrigerating machinery

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2014

Pembimbing 1 : Bustani Mustafa

Kata Kunci : activated carbon-ammonia, adsorption-desorption, bed generator

Status Posting : Published

Status : Tidak Lengkap


File Repositori
No. Nama File Hal. Link
1. 2014_TS_MTM_161128004_Halaman-Judul.pdf -1
2. 2014_TS_MTM_161128004_Lembar-Pengesahan.pdf
3. 2014_TS_MTM_161128004_Bab-1_Pendahuluan.pdf
4. 2014_TS_MTM_161128004_Bab-2_Tinjauan-Pustaka.pdf
5. 2014_TS_MTM_161128004_Bab-3_Metodolog-Penelitian.pdf
6. 2014_TS_MTM_161128004_Bab-4_Hasil-dan-Pembahasan.pdf
7. 2014_TS_MTM_161128004_Bab-5_Kesimpulan-dan-Saran.pdf
8. 2014_TS_MTM_161128004_Daftar-Pustaka.pdf
9. 2014_TS_MTM_161128004_Lampiran.pdf

P Permasalahan utama dari sistem refrigerasi adsorpsi ini adalah masih rendahnya kinerja sistem refrigerasi adsorpsi (COP), siklus refrijerasi yang masih terlalu lama, konduktivitas termal sebagian besar material absorbent relative rendah, maka terbuka luas untuk dilakukan penelitian dan pengembagannya, baik secara simulasi maupun ekperimental. Untuk meningkatkan konduktivitas termal salah satu pendekatan yang dilakukan adalah membuat desain generator untuk meningkatkan perpindahan panas. Pada penelitian ini dikembangkan suatu desain bed generator berbentuk balok empat persegi panjang, dengan pasangan adsorber-absorbat karbon aktif ammonia. Dengan waktu siklus 60 menit, perubahan temperature dan tekanan dalam bed generator mengikuti siklus desorpsi-adsorpsi Clausius Clapeyron. Waktu siklus 60 menit, sumber panas optimuam yang menghasilkan desorpsi yang baik pada temperature 80°C, proses desorpsi menguapnya ammonia dari karbon aktif terjadi pada temperature 73°C - 78°C dan tekanan 27 bar - 29 bar. Proses adsorpsi optimal diserapnya ammonia oleh karbon aktif terjadi pada tekanan 12.5 bar - 10.5 bar dan temperature generator 33°C - 31°C.

T The main problem of the adsorption refrigeration system is still low adsorption refrigeration system performance (COP), refrigeration cycle is still too long, most of the thermal conductivity of the absorbent material density is relatively low in magnitude , then open wide to research, both simulation and experimental. To improve the thermal conductivity one approach taken is to make the design generator to increase heat transfer. In this study developed a design bed generator rectangular-shaped beam, with a pair of activated carbon-ammonia . With a cycle time of 60 minutes , changes in temperature and pressure in the bed generator following the adsorption-desorption cycle Clausius Clapeyron. Cycle time of 60 minutes , optimuam heat source that produces a good desorption at temperatures of 80°C , the evaporation of ammonia desorption from activated carbon occurs at temperatures of 73°C - 78°C and pressure of 27 bar - 29 bar. Optimum adsorption process of ammonia absorbed by activated carbon occurs at a pressure of 12.5 bar - 10.5 bar and temperature generator 33°C - 31°C .

Bagaimana Anda menilai Koleksi ini ?