DETAIL KOLEKSI

Pengaruh campuran es batu dan garam pada fan coil unit (fcu) di sistem pendingin


Oleh : Rizqy Amaryansyah

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2017

Pembimbing 1 : Senoadi

Subyek : Air conditioning

Kata Kunci : cooling machine, ice cube and salt, refrigeration source, water volume, air out temperature

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2017_TA_TM_06115533_Halaman-Judul.pdf
2. 2017_TA_TM_06115533_Bab-1.pdf
3. 2017_TA_TM_06115533_Bab-2.pdf
4. 2017_TA_TM_06115533_Bab-3.pdf
5. 2017_TA_TM_06115533_Bab-4.pdf
6. 2017_TA_TM_06115533_Bab-5.pdf
7. 2017_TA_TM_06115533_Daftar-Pustaka.pdf 1
8. 2017_TA_TM_06115533_Lampiran.pdf

M Mesin pendingin udara merupakan suatu peralatan yang dapat dijumpai pada hampir setiap perkantoran, gedung-gedung, rumah tangga, dan acara indoor/outdoor. Untuk memenuhi tuntutan tersebut, maka penelitian pengaruh campuran es batu dan garam dilakukan karena untuk efisiensi pemakaian listrik dan biaya.Penelitian ini menggunakan campuran es batu dan garam sebagai sumber pendinginan. Salah satu penerapan pengaruh campuran es batu dan garam untuk pemakaian di suatu acara indoor/outdoor. Penelitian campuran es batu dan garam dimulai dengan menentukan komposisinya. apabila dari komposisi sudah sesuai maka dilanjutkan dengan menggunakan Fan Coil Unit (FCU) di sistem pendingin. Hasil penelitian campuran es batu dan garam menggunakan air dingin yang disalurkan ke Fan Coil Unit (FCU) di sistem pendingin berasal pendinginan dari es batu dan garam.Observasi studi telah menguji 3 data volume air pada Fan Coil Unit (FCU) di sistem pendingin untuk penyalur air dingin berasal pendinginan daries batu dan garam. Dari volume air 2,2 liter⁄menit, 2,5 liter⁄menit, dan 4,2liter⁄menit terdapat temperatur air masuk, temperatur air keluar, temperaturudara masuk, dan temperatur udara keluar yang berbeda-beda. Dari hasilpengolahan data dan analisa grafik didapat bahwa temperatur udara keluarterdingin adalah untuk laju aliran massa air 2,5 liter⁄menit sebesar 23,66 °Cdengan Qmax sebesar 1045,43 W dan NTU sebesar 4,28

T The air conditioning machine is an equipment that can be found in almost every office, building, household. To meet these demands, the study of the influence of the mixture of ice cube and salt was done due to the efficiency of electricity consumption and cost.This study used a mixture of ice cube and salt as a source of cooling. One application of the influence of the mixture of ice cube and salt for use in an indoor / outdoor event. The study of ice cube and salt mixtures begins with determining the composition. if the composition is appropriate then proceed with Fan Coil Unit (FCU) for cooling system. The results of a mixture of ice cube and salt using cold water channeled to the Fan Coil Unit (FCU) for cooling system derived cooling of ice cube and salt.Study observations have tested 3 water volume data on Fan Coil Units (FCU) for cooling system for cold water distributors derived cooling from ice cube and salt. From the water volume of 2.2 liter/minute, 2.5 liter/minute, and 4.2 liter/minute there is inlet temperature, outlet temperature, air temperature, and different exit air temperature. From the results of data processing and graph analysis obtained that the coldest exit air temperature is the mass transfer rate ofwater 2.5 liter/minute is 23,66 ° C with Qmax is 1045,43 W and NTU is 4,28.

Bagaimana Anda menilai Koleksi ini ?