Perancangan transformator arus untuk proteksi diferensial pada jaringan 150 kv PT. Bekaert dengan saturasi sebagai parameter


Oleh : Nabila Ainun Waluyo

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2018

Pembimbing 1 : Chairul Gagarin Irianto

Subyek : Electric engineering;Electric transformers

Kata Kunci : current transformer, knee point voltage, protection relay, factory acceptance test, restricted earth

Status Posting : Published

Status : Tidak Lengkap


File Repositori
No. Nama File Hal. Link
1. 2018_TA_STE_062001400047_Halaman-Judul.pdf 11
2. 2018_TA_STE_062001400047_Lembar-Pengesahan.pdf 3
3. 2018_TA_STE_062001400047_Bab-1_Pendahuluan.pdf 5
4. 2018_TA_STE_062001400047_Bab-2_Tinjauan-Pustaka.pdf
5. 2018_TA_STE_062001400047_Bab-3_Metode-Penelitian.pdf
6. 2018_TA_STE_062001400047_Bab-4_Analisis-dan-Pembahasan.pdf
7. 2018_TA_STE_062001400047_Bab-5_Kesimpulan.pdf
8. 2018_TA_STE_062001400047_Daftar-Pustaka.pdf 1

R Rele proteksi digunakan untuk melindungi jaringan dari berbagai gangguan listrik,baik eksternal maupun internal. Rele tersebut akan bekerja apabila mendapat informasi arus yang dikirimkan oleh Transformator Arus sehingga penentuan spesifikasi suatu Transformator Arus akan sangat menentukan bagaimana releproteksi dapat bekerja dengan benar. Untuk proteksi Utama seperti relediferensial, rele jarak dan rele gangguan tanah terbatas, perlu dilakukanperancangan spesifikasi dari trafo arus atau sizing transformator arus dan kalkulasi saturasi sebagai parameter utama suatu Transformator Arus untuk memastikan bahwa Transformator Arus akan dapat bekerja dalam memberikan informasi dalam keadaan gangguan. Sizing dan kalkulasi saturasi dari sebuah transformator arus ditentukan sejak tahap desain. Hal tersebut dilakukan pada penelitian ini dengan menhitung nilai arus primer, rasio transformator arus, nilai arus gangguanpada jaringan, nilai lead resistance, mencari tahu faktor remanansi dan menghitung titik saturasi untuk bisa di bandingkan dengan hasil Factory Acceptance Test. Parameter yang didapatkan untuk menghitung titik saturasi tersebut lead resistance (RL), faktor remanansi (K), resistansi rele (RR) danresistansi dalam transfomator arus (RCT) Berdasarkan hasil perhitungan titiksaturasi transformator arus dan membandingkan hasilnya dengan FactoryAcceptance Test, didapat nilai titik saturasi transformator arus hasil perhitungandibawah nilai titik saturasi hasil Factory Acceptance Test maka transfomator arusdianggap sudah mencukupi kebutuhan.

P Protection relays are used to protect the network from various electricaldisturbances, both external and internal. The relay will work if the currentinformation is sent by the current transformer so that the determination of thespecifications of a current transformer will determine how the protection relay canwork correctly. For main protections such as differential relay, distance relay andrestricted earth fault relay, it is necessary to design specifications of currenttransformers or sizing current transformers and saturation calculations as the mainparameters of a current transformer to ensure that the current transformer will beable to work in providing information in fault conditions. Sizing and saturationcalculations of a current transformer are determined from the design stage. Thiswas done in this study by calculating the value of the primary current, the ratio ofthe current transformer, the value of the current fault on the network, the value ofthe lead resistance, find out the dimensioning factor and calculate the knee pointvoltage to be compared with the results of the Factory Acceptance Test.Parameters for calculating the saturation point are lead resistance (RL), remittancefactor (K), relay resistance (RR) and resistance in current transformer (RCT).33qwBased on the calculation of the current transformer knee point voltage andcompare the results with the Factory Acceptance Test, the knee point voltage ofcurrent transformer value obtained from the calculation is no more higher thanknee point voltage point value of the Factory Acceptance Test results, the currenttransformer is considered sufficient.