DETAIL KOLEKSI

Perbandingan performa mesin pendingin dengan beban unit penukar kalor menggunakan refrigerant r-12, r-134a, dan mc-134


Oleh : Nata Octariansyah

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2019

Pembimbing 1 : Rosyida Permatasari

Subyek : Cooling systems

Kata Kunci : heat exchanger, refrigerant, r-12, r-134a, mc-134

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2019_TA_STM_06112012_Halaman-Judul.pdf
2. 2019_TA_STM_06112012_Lembar-Pengesahan.pdf
3. 2019_TA_STM_06112012_Bab-1_Pendahuluan.pdf
4. 2019_TA_STM_06112012_Bab-2_Tinjauan-Pustaka.pdf
5. 2019_TA_STM_06112012_Bab-3_Metodologi-Penelitian.pdf
6. 2019_TA_STM_06112012_Bab-4_Analisis-Hasil-dan-Pembahasan.pdf
7. 2019_TA_STM_06112012_Bab-5_Kesimpulan-dan-Saran.pdf
8. 2019_TA_STM_06112012_Daftar-Pustaka.pdf
9. 2019_TA_STM_06112012_Lampiran.pdf

U Unit penukar kalor merupakan unit yang berfungsi untuk memindahkan energipanas antara dua atau lebih fluida dan terjadi pada temperatur yang berbeda antarfluida, dimana fluida tersebut ada yang bertindak sebagai fluida panas (hot fluid)dan yang lain bertindak sebagai fluida dingin (cold fluid). Dalam penggunaan AC(air conditioner) diperlukan refrigeran yang berfungsi sebagai media pendingin danmengalami proses penguapan sekaligus menyerap panas. Penelitian ini bertujuanmengetahui performa mesin RLU (Refrigeration Laboratory Unit) dengan bebanunit penukar kalor menggunakan refrigeran R-12, R-134a, dan MC-134 denganmembandingkan nilai COP (Coefficient of Performance) yang diperolehberdasarkan daya input motor, daya input poros, daya input indikasi, dan siklusideal. Dari hasil pengujian didapatkan bahwa refrigeran MC134 menghasilkan COPpaling besar dibandingkan dengan refrigeran R12 dan R134a.

H Heat exchanger is a unit which serves to move heat energy between two or morefluid and occurring at different temperatures between fluid, where fluid in questionthere who acts as hot fluid and other acts as a cold fluid. In AC (Air Conditioner)needed a refrigerant that serves as a medium cooling and undergo a evaporation andabsorb heat. This research aims to find out the engine performance RLU(Refrigeration Laboratory Unit) through a heat exchanger to use a refrigerant R-12,R-134a, and MC-134 by comparing the value of those obtained from COP(Coefficient of Performance) obtained based on electric motor input, shaft power,indicated power, and ideal cycle. Based on the test results, COP of MC134refrigerant has the highest value compared to R12 and R134a refrigerants

Bagaimana Anda menilai Koleksi ini ?