DETAIL KOLEKSI

Masa pengoperasian optimal penyaring udara Filtrair CTJS-150 yang dipasang pada unit indoor AC Eolia model CS-E715K


Oleh : Roseline Jahja

Info Katalog

Penerbit : FALTL - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2001

Pembimbing 1 : Budi Rahayu

Pembimbing 2 : Muhammad Lindu

Subyek : Air filter media;Synthetic fiber - Based filter mats

Kata Kunci : gravimetric method, filter CT15-150

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2001_TA_TL_08292033_Halaman-Judul.pdf
2. 2001_TA_TL_08292033_Bab-1.pdf
3. 2001_TA_TL_08292033_Bab-2.pdf
4. 2001_TA_TL_08292033_Bab-3.pdf
5. 2001_TA_TL_08292033_Bab-4.pdf
6. 2001_TA_TL_08292033_Bab-5.pdf
7. 2001_TA_TL_08292033_Daftar-Pustaka.pdf
8. 2001_TA_TL_08292033_Lampiran.pdf

P Pada penelitian ini dilakukan pengujian terhadap sejenis media penyaring udara yaitu FILTRAIR CTJ 5-150. Penyaring udara ini diuji pada AC Tipe Split Wall Mounted Model CS-E7 l 5K produksi Eolia - National yang berada di dalam ruangan kantor pada pabrik percetakan di Kawasan Industri Kapuk Kamal, Cengkareng. Pengamatan dilakukan pada 2 buah ruangan yang berbeda luas (21 m2 dan 14 m2) dan aktivitasnya, walaupun masing-masing ruangan dihuni oleh 1 penghuni. Aktivitas ruang - 1 adalah membuat contoh rancangan produk stationary berbahan kertas, sedangkan ruang - 2 merniliki ~ktivitas adrninistrasi biasa. Hal in.i mendorong perkiraan bahwa ukuran partikel de u yang tersebar pada masing-masing ruangan pun berbeda. Pengujian dilakukan de1 an cara mengukur jumlah partikel debu yang terakumulasi pada FILTRAIR CTI5 - 150 selarna 8 minggu dengan metode gravimetri,dan juga menghitung pertambambahan debu yang terjadi setiap minggunya pada penyaring udara tersebut. Setelah 8 minggu diperoleh hasil bahwa di ruang_1 jumlah partikel debu yang terakumulasi adlah 0,5337 gram/m2. dan pertambahan debu rata-rata setiap minggunya adalah 0,0918 gram/m2. Terlihat jelas pada grafik yang menampilkan data pertambahan partikel debu yang terakumulasi pada penyaring udara di masing-masing ruangan, bahwa kemampuan penyaringan FILTRAIR CT15 -150 yang optimal terjadi setelah 4 minggu beroperasi. Nampak pada grafik diata, titik tertinggi atau pertambahan terbanyak terjadi antara minggu ke-3 dan ke-1, selanjutnya terjadi penurunan. Ini menunjukkan bahwa media penyaring memiliki kemampuan optimal menangkap debu dengan kondisi di ruang -1 dan 2 adalah setelah beroperasi selama 4 minggu. Pada grafik di bawah ini nampak jelas FILTRAIR CT15 -150 tersebut suatu saat akan mencapai titik jenuhnya, dimana hampir tidak ada lagi partikel debu yang ditangkap.

T This research was done to the FJLT/WR CTJ 5-150 air filter media that developed from synthetic fiber-based filter mats. The filter media are constructed from selected fibers in a progressive density multi-layering technique, and it's a11owed to be re-used many times after washing. The FILTRAJR CTJ 5-150 attached to EOLIA CS-E7 l 5K model airconditioner tbat settled in two office rooms at P.T. Tiga Warna Gempita printing fabric and recycles paper-based stationary making, at Kapuk Kamal Industrial Region, Cengkareng. Operating for 8 weeks during working hour, Monday until Friday, from9:00 a.m. until 5:00 p.m.Every office room has a me model air conditioner, same level side-to-side,and occupied by only one person. But there are different activities, interior, and room area. It indicated the different distribution of dust particle size between those two room. Room 1 which activity wasd esigning and making mock -up of recycles paper -based stationary, has 21 square meter area, and room -2 which only has normal administration activity, has 14 square meter area. There were three points in the research. To measure the accumulation of dust particle that had been holding on the air filter media by gravimetric method, to know for how long the air filter media can perform optimally by observing method, to know for how long the air filter media can perform optimally by observing the growth of dust particles in every week, and last was topredicting satiation time of air filter media by expontial relationship for mathematical mode. After 8 week, the accumulated dust particles at room1 were 0,5337 grams per square meter, and averages growth of the dust particles were 0,0667 grams per square meter every week. At room-2, the accumulated dust particles were 0, 7346 grams per square meter and 0,0918 grams per square meter every week for averages growth of dust particles. Clearly on graphic below that shown data for averages growth of dust particles accumulated ob filter media for every room, that optimum time of FILTRAIR CT15-150 filtration capacity occured after had being operated for 4 weeks.