Pengaruh penggunaan kondensor dengan membandingkan hasil kondensor udara dan kondensor ecaporatif terhadap pendinginan AC KRL seri 6000 hibah


Oleh : Briyan Indra Anjasmoro

Info Katalog

Penerbit : FTI - Usakti

Kota Terbit : Jakarta

Tahun Terbit : 2014

Pembimbing 1 : Senoadi

Subyek : Cooling performance - evaporative method;Air conditioning - system and component

Kata Kunci : air cinditioning (AC), condender, KRL, quality

Status Posting : Published

Status : Lengkap


File Repositori
No. Nama File Hal. Link
1. 2014_TA_MS_06108026_Halaman-Judul.pdf
2. 2014_TA_MS_06108026_Bab-1.pdf
3. 2014_TA_MS_06108026_Bab-2.pdf
4. 2014_TA_MS_06108026_Bab-3.pdf
5. 2014_TA_MS_06108026_Bab-4.pdf
6. 2014_TA_MS_06108026_Bab-5.pdf
7. 2014_TA_MS_06108026_Daftar-pustaka.pdf
8. 2014_TA_MS_06108026_Lampiran.pdf

P Pengguna jasa Kereta Rel Listrik (KRL) mengeluhkan Air Conditioner (AC) di beberapa gerbong yang tidak berfungsi maksimal. Disaat pagi hari dimana penumpang melalkukan aktivitas sehari-hari untuk berangkat sekolah, bekerja dan sebagainya. Dan disaat sore hari disaat penumpang kembali kerumah masing-masing. Disaat waktu inilah AC kereta tidak bisa bekerja dengan maksimal. Tentu ada faktor-faktor yang menyebabkan AC kereta tidak bekerja maksimal. Oleh karena itu dilakukan penelitian dengan satu tipe kereta yaitu KRL seri 6000 hibah.Tujuan dari penelitian ini adalah untuk mengetahui efisiensi pendinginan terhadap performansi AC Kr! dengan membandingkan kondensor udara dan kondensor dengan menggunakan metode evaporatif. Juga untuk mengetahui perbandingan besaran efek refrigerasi, laju aliran massa refrigeran, beban pendingin, COP dan rasio kompresi dengan membandingkan kondensor udara dan kondensor dengan menggunakan metode evaporatif.Setelah melakukan penelitian, maka ditemukan bahwa kondensor dengan metode evaporatif diharapkan dapat menggantikan kondensor udara tanpa merubah komponen mesin pendingin. Dikarenakan dari hasil pengujian kondensor evaporatif dapat menghemat listrik dan mempunyai Coeffisien Of Performance yang lebih besar.

U Users of the services of Krl (KRL) complained of the Air Conditioning (AC) on some cars that do not function optimally. When the morning where passengers depart for daily activities of the school, work and so on. And when the evening when passengers back home each. During this time that the train could not work Air Conditioning with a maximum. There are certainly factors that cause the train Air Conditioning does not work optimally. Therefore conducted research with one type of train that KRL Series 6000 grants.The purpose of this research is to know the efficiency of the cooling performance of the Air Conditioning against KRL by comparing air condenser and condenser by using the evaporatif method. Also to know the comparative magnitudes of effects of refrigeration, refrigerant are mass flow rate, cooling loads, COP and compression ratio by comparing the air condenser and condenser by using the method of evaporative. After doing some research, it was found that the condenser by the method of evaporatif is expected to replace the condenser air without changing the components of the engine coolant. Because of the results of the testing of a condenser evaporatif can save electricity and have coeffisien of the performance of a larger.